DIN Miniature RCBO's |
| | |
QF Range
|

View Data Sheet
|
Applications
- The QF range of MCB’s and RCBO’s are for use against overload, short circuit and residual current (QF10 only) protection in residential, commercial, industrial and mining applications.
Features
- Precision circuit breaker utilizing hydraulic magnetic technology
- DIN mounting
- Always carry 100% of rated current. Trip point un-affected by ambient temperature
- Mid-trip handle indication signifies breaker operation for electrical fault
- Immediate resetting can be done after clearance of fault (No thermal memory)
- No ageing deterioration of sensing mechanism which is hermetically sealed
- IP2X terminals
- Handle is sealable and padlockable (with padlock attachment)
- Suits HQFC chassis - 250A rated
- RCBO is suitable for applications with pulsating DC components
- RCBO insulation resistance testing can be done with handle in the off position - no disconnection of the unit is required
|
|
DIN Miniature RCCB's |
| | |
RCCB Range
|

|
Features
- RCCB's Comply with AS/NZS 3190
(Approval Number N15040)
- 6kA withstand capacity in combination with
63A fuse or 6kA MCB upstream
- 36mm width – 2 pole unit
- 72mm width – 4 pole unit
|
|
2 Pole Miniature RCBO's: Combined RCD/Circuit Breakers |
| | |
SF1EL : HEINELEC Range
|

View Data Sheet
|
Applications
- Provides 30mA residual current protection with active and neutral isolation combined with overload and short circuit protection
Features
- Complies with AS 3111 & AS/NZS 3190
(Approval Number NSW21007)
- Switches both the Active and Neutral Poles
- 26mm Width
- Hydraulic-magnetic circuit breaker : Overcurrent trip point
unaffected by ambient temperature
- IP2X Shrouded line and load terminals
- Operating voltage: 110V to 240V AC (50Hz/60Hz)
- Immune to pulsating DC
|
|
SA15A
|

|
Applications
- Provides 30mA residual current protection with active and neutral isolation combined with overload and short circuit protection. Will operate on earth leakage even in the case of a lost neutral conductor.
Features
- SA15A approved to AS 3111 and AS/NZS 3190
(Approval number N15266)
- Switches both the Active and Neutral Poles
- Hydraulic-magnetic circuit breaker : Overcurrent trip
point unaffected by ambient temperature
- Immune to pulsating DC
- Unit supplied with 2 adaptor plates for clip tray
mounting and active link for busbar connection
- 52mm (2 Pole) width
- Functional Earth (FE) for loss of Neutral operation
|
|
SF15AE - SF15CE
|

|
Applications
- Provides 30mA residual current protection with active and neutral isolation combined with overload and short circuit protection. Will operate on earth leakage even in the case of a lost neutral conductor
Features
- SF15AE approved to AS 3111 and AS/NZS 3190
(Approval number N15215)
- SF15CE approved to AS/NZS 3190 (Approval number N15216)
- Switches both the Active and Neutral poles
- Hydraulic-magnetic circuit breaker : Overcurrent trip point
unaffected by ambient temperature
- Immune to pulsating DC
- Unit supplied with 2 adaptor plates for clip tray mounting
and active link for busbar connection
- 78mm (3 Pole) width
- Functional Earth (FE) for loss of Neutral operation
|
|
SM15A
|

|
Applications
- Provides 100mA or 500mA residual current protection with active and neutral isolation combined with overload and short circuit protection. Will operate on earth leakage even in the case of a lost neutral conductor
Features
- SM15A approved to AS 3111 and AS/NZS 3190
(Approval number N15215)
- Switches both the Active and Neutral Poles
- Hydraulic-magnetic circuit breaker : Overcurrent trip point
unaffected by ambient temperature
- Immune to pulsating DC
- Unit supplied with 2 adaptor plates for clip tray mounting
and active link for busbar connection
- 78mm (3 Pole) width
- Functional Earth (FE) for loss of Neutral operation
|
|
4 Pole Miniature RCBO's: Combined RCD/Circuit Breakers |
| | |
SF36AE - SF36CE
|

|
Applications
- Provides 30mA residual current protection with active and neutral isolation combined with overload and short circuit protection. Will operate with either two phases or any one phase and neutral present
Features
- SF36AE approved to AS 3111 and AS/NZS 3190
(Approval number N15215)
- SF36CE approved to AS/NZS 3190
(Approval number N15216)
- Switches all Active and Neutral Poles
- Hydraulic-magnetic circuit breaker : Overcurrent
trip point unaffected by ambient temperature
- Immune to pulsating DC
- Unit supplied with 3 adaptor plates for clip tray
mounting, Pole filler and active link for busbar connection
- 130mm (5 Pole) width
|
|
SM36A - SM36C
|

|
Applications
- Provides 100mA, 250mA & 500mA residual current protection (SM36A) with active and neutral isolation combined with overload and short circuit protection. Will operate with either two phases or any one phase and neutral present
Features
- SM36A approved to AS 3111 and AS/NZS 3190
(Approval number N15215)
- SM36C approved to AS/NZS 3190
(Approval number N15216)
- Switches all Active and Neutral Poles
- Hydraulic-magnetic circuit breaker : Overcurrent trip point
unaffected by ambient temperature
- Immune to pulsating DC
- Unit supplied with 3 adaptor plates for clip tray mounting,
pole filler and active link for busbar connection
- 130mm (5 Pole) width
|
|